The unique circuitry of the 750 Series II Conductivity Monitor/controllers guarantees accurate and reliable measurements. Drift-free performance is assured by “field proven” electronics, including automatic DC offset compensation and highly accurate drive voltage. Since temperature compensation is at the heart of accurate water measurement, all Myron L® Monitor/controllers feature a highly refined and precise TC circuit. This feature perfectly matches the water temperature coefficient as it changes. All models corrected to 25°C. The TC may be disabled to conform with USP requirements.
Built-in electronic calibration allows for fast quality checks without standard solutions. (Note: for maximum system accuracy standard solutions are recommended). A push-to-test button makes setpoint checks easy, while the internal alarm set discourages unauthorized adjustments.
Standard on all controller models is a heavy-duty 10 amp output relay, operating on either increasing or decreasing readings. Bright green/red LEDs indicate above or below setpoint readings. All 750 Series II models feature an IP65/ NEMA 4X water resistant and corrosionproof rated enclosure. Compact in size at 152 x 122 mm/6 x 4.8 in., they are suitable for panel, bench or surface mounting.
Additional options include a 3 Sensor Input Switch and/or a 3 Range Switch and a Remote Alarm™ model RA.
These reliable sensors feature an integral temperature sensor to ensure accurate and rapid automatic temperature compensation. The sturdy polypropylene bushing is modular for easy inexpensive replacement. Several alternatives for the metal portion of the sensor are available, depending on the demands of the application.
Ranges | 34 ranges from 0-1 ppm/μS (μM) to 0-200 ppt/mS (mM) |
See Price List for further details. | |
Display | Analog Models: 2.5 in./63 mm meter |
Digital Models: .5 in./13 mm 3½ Digit LCD | |
Digital Option: 3½ or 4½ Digit Backlit | |
Accuracy | Analog Models: ± 2% of full scale |
Digital Models: ± 1% of full scale | |
Sensitivity | 0.05% of full scale |
Stability | 0.05% of full scale |
Repeatability | 0.1% of full scale |
Calibration Check | Built-in |
Recorder Output | 0-10 VDC @ 5 mA max. (linear); standard all models |
Sensor Inputs | 1 (3 input option available) |
Control Function | Single Alarm/controller fully adjustable 0-100% of full scale |
Hysteresis: Adjustable from 0.3-3% of full scale | |
Indicators: Above (red) and below (green) setpoint LEDs (reversible) | |
Contact Rating: SPDT 10 amp @ 250 VAC, 30 VDC. Relay operates decreasing or increasing reading (selectable). | |
Second Alarm/controller, with above specifications – optional | |
Solid State Output | Powered; 24 VDC unregulated 30 mA max. |
Power | 115/230 VAC, 50/60 Hz, ±15% (user selectable) |
24 VAC optional | |
Maximum Power Consumption | @ 115V: 100 milliamps |
Dimensions | 152 H x 122 W x 96 D mm / 6 H x 4.8 W x 3.8 D in. |
Construction | Fully gasketed heavy-duty ABS case; water resistant and corrosion proof IP65/NEMA 4X rated |
Ambient Temp Range | 0-60°C / 32-140°F |
Weight | 0,9 kg/2 lbs. |